Caitlin Napoleoni Wedding Photos, Medical Futility Laws By State, Ghost Town Crips Pomona, Latin Abbreviations In Church Records, Romantic Things To Do In Asheboro, Nc, Articles H

Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. Hi Davy, I dont know if Im convinced the new pump is bad or not, or if I need higher voltage to the pump. If your salt system is hardwired, variations in voltage could cause the controller to go a little haywire. Any idea why this might be happening? Pump Surging also occurs from low water level, or air leaks in front of the pump. Humming Motor: If the pump motor makes a humming sound when starting up, you likely have a clogged impeller. Humming noise is usually associated with a bad capacitor, a black cylinder at 9 oclock in the rear of the motor. Just wired and installed a brand new Century 1 hp pump motor on a Hayward Super pump filter, getting power to the terminals of the motor but motor does not start, shaft spins freely. All components of the Aqua Rite System are showing good readings and appears to be all set correctly. Is the wire size correct? You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. Anything I can do on my own to fix this? (I just bought the house and am new to pool upkeep.). Look at the diagram on the top center of the motor, which may provide some help, if not, call Hayward (908) 355-7995 (U.S.). You can use a pool putty to seal up some incoming leaks, but sometimes new parts are needed. If power is reaching the box, getting past the transformer, and the fuse is good, it sounds like the main PCB is the issue. Hi Tom, if it is the same exact pump and pump size, that would be unusual, but if its the same horsepower, but a different pump model, that would be the simplest answer. If the motor is still giving you a drive stall error, it probably means that you need a new drive. You can check power in, on the incoming wires, and power out (with timer ON), on the outgoing wires that go to the motor. Shock the pool first and overfilter, before pulling pump. No power not even a humming. If thats not it pull the motor out of the pump, and test the motor briefly to see if the sound continues, if so I would expect bad bearings, or perhaps a loose shim washer, inside the motor, under the front or rear end bell. Hi Davy, I have a Hayward Super II which has been running well for years. I have a pre-2008 Northstar pump and it seems to be losing air seal. 99% of the time its no problem 1% of the time something could burst, usually a plumbing fitting, a bad glue joint or clamped fitting. Have an old Hayward super II pump, worked fine last fall, this spring at startup very low volume. I removed the capacitor and had it tested at a local pool store and they told me it was fine. "@type": "ImageObject",
The motor spins CCW? It has the switch at the bottom to turn on along with the built in timer. If power is tested at these points, I would check the motor terminals. I replaced the capacitor last year. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Does it sound like the capacitor or could something else be the culprit? When the centrifugal switch is pushed flat by the spinning shaft (or with your finger [power off!