If a steel sleeve is fitted, the gap between the sleeve and the duct must be fully packed with a non-combustible material and the sleeve's ends must be sealed with a fire-retardant flexible sealant. Locate extinguishers so they are readily accessible to employees for immediate use. Min capacity of foam is 9l. > One of the P.F.E intended for use in any space shall be stowed near the entrance to that space. Spare charges and Refilling for portable fire extinguishers, Further details may be found by reading relevant Technical Information, Your email address will not be published. Using Medicaid With Medicare Or Other Medical Insurance, Eight Ways To Teach Gratitude And A Gratitude Jar Craft, GW Orthopaedic Surgeon Discusses Total Knee Replacement, United Ways Team Up To Stock Local Pantries This Summer, Straight Forward Pricing For Comprehensive Primary Care, Our Content Is Developed And Thoroughly Reviewed By PMP, Obblighi Di Trasparenza Con La Pubblica Amministrazione, KRA Announces New Revenue Collection System For Nairobi. 3.8.5.1 Every vessel must display "mimic" plans in accordance with regulation 13.7.2.2 and must also display those plans in every space occupied by the crew. PDF 1300 88 3473 | www.firesys.com.au | info@firesys.com Is carrying more than 25 berthed passengers or more than 50 passengers, or. google_ad_slot = "8641225286"; Any other vessel of less than 500 gross tonnage must be provided with one hydrant in each machinery space of category A. Holds the fire extinguisher securely in place but provides quick and positive release of the fire extinguisher for immediate use. 3.5.1.1 The class divisions requirements of regulation 9.2.3.4 for stairways and lift trunks that penetrate more than a single deck apply to any area, such as a landing or corridor, between the stairways or lift trunks, if feasible. Has clearly stamped on it the door manufacturer's name, the "A" or "B" class rating, the type approval certificate number and the number of the drawing to which the door has been manufactured, and. Spare charges and Refilling for portable fire extinguishers (1) Spare charges shall be provided for 100% of the first 10 extinguishers and 50% of the remaining fire extinguishers capable of being recharged onboard. 2.1.1.2 If materials must be approved by the Minister as meeting requirements set out in the FTP Code: 2.2.1.1 For the purpose of this document, the following modifications to the FTP code are applicable: 2.2.1.2 For "A" class divisions" the insulation on the decks and bulkheads is to be held in place in accordance with the certificate of approval and manufacturer's instructions by closely spaced studs and clips, or by other means, that will hold the insulation in place taking into account the vibration and motion of the vessel and the normal wear. 1432) X . For extinguishing this class of fire, the sleeve needs to extend beyond the length of the pipe, crewmen must maintain a safe distance from the fire unless they are properly protected and equipped for the attack. Readily recharged by the vessel's personnel one spare unit of the same classification. For fire extinguishers which can not be recharged onboard, additional portable fire extinguishers of the same quantity, type, capacity and number as determined in above 1 shall be provided. 0000001466 00000 n The emergency fire pump must be provided with its independent suction arrangement and the total suction head should not exceed 4.5 meters under all conditions of list or trim The emergency fire pump capacity to be at least 25m3/hr delivering two inches bore jet of water having a horizontal throw not less than 40 ft Might not be required when any other part of the fire main is used. In the working language of the vessel, and.